Vista de pagina 0
128-7853A
1 of 16
1
Model APS-920
Installation Manual
This Remote Start/Alarm System is designed to be used with
Automatic Transmission-Fuel Injection Vehicles Only!
COMPONENTS:
Control Module
1 Four Button RF Transmitter
1 Four Button LCD Transmitter
2 Way Antenna/Receiver
1 “1 X 1.75” Foam Pad
6 Pin Main Power Harness w/Fuses
20 Pin Accessory Harness
1 Hood Pin Switch
1/4” Female Spade Connector
2 Pin Door Lock/Unlock Harness
Starter Inhibit Relay & Harness
2 Pin LED Assy
2 Pin Push-Button Valet/Program Switch
4 Pin Antenna Receivers Harness
4 Pin Auxiliary Output Harness
Installation/Owners Guide
4 Philips Head Black Drill Point Sheet
Metal Screw #8 X 1/2"
FEATURES:
Selectable Ignition Lock & Unlock
Selectable Door Lock/Unlock Output Timing
Safe Start (Requires double push of the start button to engage the remote start function)
On Board Parking Light Relay
Trunk Release Output
Horn Chirp Output With Duration Select
Selectable RF Start Chirp
Panic Mode (Can select to have horn along with parking lights)
Selectable Run Times 5, 10, 15, or 20 Minutes
Selectable Gas or Diesel
Automatic Start Timer (Can be set to start your car automatically at 2 or 4 hour intervals)
4 Negative Pulsed Aux Outputs Before Start, After Start, During Crank, After Shut Down
(To aid installation in many vehicles with factory alarm systems)
Turbo Timer
Dual Stage Shock Sensor
Shock Sensor Shunt During R/S Selectable
FCC NOTICE
This device complies with part 15 of the FCC rules. Operation of this device is subject to the
following conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for
compliance voids the users authority to operate this device.
Rev A To Include + Door Lock Outputs Reference Omitted In The Original Draft 7/23/08
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Model APS-920

128-7853A1 of 161Model APS-920Installation ManualThis Remote Start/Alarm System is designed to be used withAutomatic Transmission-Fuel Injection Vehi

Pagina 2

128-7853A10 of 1610The Light Blue wire can be used to accommodate the following situations:A. Shock Sensor By Pass:B. Additional Ignition Output:C. GM

Pagina 3

128-7853A11 of 16114 Pin Shock Sensor Connector “D”Red, Black Green & Blue wires of the shock sensor harness provide +12 Volts, Ground, FullTrigge

Pagina 4

128-7853A12 of 1612

Pagina 5

128-7853A13 of 16133 Wire Positive Switched Door Lock Circuits:In this application, the Red wire of the 2 pin harness provides a Positive pulse during

Pagina 6

128-7853A14 of 1614Setting Up The System Programming Features:Bank 1 Transmitter ChannelsStart with the system disarmed, tun the ignition switch to th

Pagina 7

128-7853A15 of 1615Programming Tach Rate:NOTE: All applications require that tach be programmed.The unit will not operate unless tach is programmed.

Pagina 8

128-7853A16 of 16163. Within 10 seconds of the key turning off, cycle the enable switch Off, On, Off, On ( 2 times) toselect a 2 hour timed start inte

Pagina 9

128-7853A2 of 162INSTALLATION OF THE MAJOR COMPONENTS:CONTROL MODULE:Select a mounting location inside the passenger compartment (up behind the dashbo

Pagina 10 - 10 of 16

128-7853A3 of 163SIREN:Select a location in the engine compartment that is not accessible from below the vehicle. Theselected location must be clear

Pagina 11 - 11 of 16

128-7853A4 of 164DO NOT PLUG THE SIX PIN MAIN POWER HARNESS OR THE MULTI PIN INPUT/OUTPUTHARNESS INTO THE CONTROL MODULE UNTIL ALL CONNECTIONS TO THE

Pagina 12 - 12 of 16

128-7853A5 of 165BLUE Wire: Ignition 1 OutputConnect this wire to the ignition 1 wire from the ignition switch. This wire will show +12 voltswhen th

Pagina 13 - 13 of 16

128-7853A6 of 166false triggering of the factory alarm when the remote start unit engages or when the transmitteris used to unlock the doors.NOTE: Th

Pagina 14 - 14 of 16

128-7853A7 of 167Orange: Ground While Armed OutputThis wire provides a 300 mA ground output when the alarm circuit is armed to control thestarter inhi

Pagina 15 - 15 of 16

128-7853A8 of 168Brown Wire: Negative Door TriggerIf the vehicle's door courtesy light switches ground when the door is opened, (Most GMs andImp

Pagina 16 - 16 of 16

128-7853A9 of 169Green/Yellow Wire: DIESEL WAIT TO START INPUTThe green/yellow wire, when connected to the wire that get + 12 volts during the glow p